Launching Dental Biomaterials in a New Market

A step-by-step plan for distributors launching a dental bone graft and collagen membrane line in a new market, from registration to first accounts and review.

Launching a dental biomaterials line in a new market works as a sequence: secure registration, map the market, prepare the team, launch with a focused group of accounts, then review and expand. For DESU's COLL-OS membrane and XENOBONE graft, the manufacturer provides documents and training; the distributor brings knowledge of the market and its customers.

Key takeaways

  • Start with registration and documents; they usually set the timeline.
  • Map the market: accounts, procedures, competitors and buying routes.
  • Launch with a focused group of accounts and support their first cases closely.
  • Review after the first months and adjust stock, segments and messages.

This article sets out a practical launch plan for distributors introducing COLL-OS and XENOBONE, or a similar graft and membrane line, in a country where they are new.

Why does registration come first?

In most markets, a medical device cannot be sold until it is registered or its certification is accepted. Registration often takes longer than every other launch step. Start it as early as possible, using the manufacturer's documents: CE certificate, declaration of conformity, ISO 13485 certificate, instructions for use, labelling and, for these bovine collagen products, information relevant to the ISO 22442 series.

While registration runs, the rest of the plan can be prepared, so the team is ready when approval arrives.

Check customs and import requirements at the same time. Products containing bovine material may need additional import documents in some countries, separate from device registration. Discovering this when the first shipment reaches the border delays the launch and can leave a trained team with nothing to sell. A short conversation with a customs broker early in the process avoids the problem.

How should the market be mapped?

Before choosing target accounts, understand the market:

QuestionWhy it matters
How many practices and departments graft regularly?Size of the opportunity
Which procedures are most common?Format mix to stock
Who decides: clinicians, chains, hospitals?Sales approach
Which products are used today?Positioning
How are tenders run?Hospital strategy
What promotional rules apply?Compliant marketing

Sources include the distributor's own customer base, professional societies, congress attendance lists and conversations with key clinicians.

How should target accounts be chosen?

Launch with a focused group rather than the whole market. Good first accounts:

  • Graft regularly, so the products are used often enough to form a view.
  • Are open to trying a new product.
  • Are respected by colleagues, so their experience carries weight.
  • Are within reach for close support.

A small number of well-supported accounts generates more credible feedback than a large number visited once.

Write the target list down, with a named rep for each account and a planned date for the first visit. A launch without a written list tends to drift toward the easiest accounts rather than the right ones, and progress becomes hard to measure.

How should the team be prepared?

Train the sales team before launch on:

  • Product facts: XENOBONE is a bioresorbable, osteoconductive graft of Type I bovine collagen with β-TCP, in 0.7–1.5, 2–3 and 4–5 mm particles in 5 cc units; COLL-OS is a barrier membrane of pure Type I bovine collagen, biodegradable, ready to use, gamma sterilised, in four sizes.
  • Clinical background in general terms: guided bone regeneration and common procedures.
  • Compliance: approved claims, sample handling, complaint routes.
  • Field skills: questioning, presenting briefly, supporting first cases.

Prepare local materials at the same time: product sheets, price lists, order forms, all within local promotional rules.

How should the first stock order be planned?

Base the first order on the target accounts and their likely case mix, not on an even split of formats. Include enough stock to support first cases with backup sizes. Agree with the manufacturer how replenishment will work as orders build.

Under the EU Medical Device Regulation, and similar rules elsewhere, distributors must verify products at goods-in and keep supply records. Set up these processes before the first shipment arrives. Our article on MDR compliance for distributors sets out the duties.

How should the launch itself run?

Run the launch in stages:

  • Visit target accounts, present the products and offer samples or first-case support.
  • Support first cases closely, with the right formats on hand.
  • Collect feedback systematically after each first case.
  • Hold a small educational event, such as a hands-on session with a respected clinician, if the market supports it.
  • Expand to similar accounts once the first group is established.

Keep the manufacturer informed of progress, questions and feedback. Early feedback from a new market is valuable for both sides. A short monthly update covering accounts visited, first cases, orders and open questions is usually enough.

When should the launch be reviewed?

Review after the first few months:

  • Which accounts adopted the products, and which did not, and why.
  • Which formats moved, and which sat in stock.
  • Which questions came up repeatedly.
  • Whether any complaints arose and how they were handled.

Adjust stock, target segments and messages based on what you learn. Share the review with the manufacturer, and agree the next stage of the plan together in writing. Our article on strategic sourcing from a reliable manufacturer covers how a manufacturer supports distributors as volumes grow.

Talk to a DESU product specialist

To discuss launching COLL-OS and XENOBONE in a new market, including registration documents and training, write to sales@desu.tr, use the contact page, or request a quote.

Frequently asked questions

Can marketing start before registration is granted?

In many markets, promoting an unregistered device is restricted. Prepare materials during registration, but check local rules before using them.

How many accounts should a launch start with?

As many as the team can support closely. For a new graft and membrane line, a focused group of regular grafting accounts is usually more effective than a broad approach.

Should the launch include both products?

Usually yes, since many clinics that graft also use a membrane. Some distributors start with one and add the other once the first is established.

What is the most common cause of launch delays?

Registration and import documents. Starting registration early and checking customs requirements for bovine-derived products before the first shipment avoid most delays.

Related standards

  • Regulation (EU) 2017/745 on medical devices (MDR)
  • ISO 13485: Medical devices — Quality management systems
  • ISO 22442 series: Medical devices utilizing animal tissues and their derivatives