XENOBONE 5 cc Units: Planning Orders by Particle Size

How distributors and clinics plan XENOBONE orders in 5 cc units across three particle sizes: estimating use, setting reorder points and avoiding waste.

XENOBONE is supplied in 5 cc units, in each of its three particle sizes: 0.7–1.5 mm, 2–3 mm and 4–5 mm. Planning orders means estimating how many units of each particle size an account uses over a period, setting a reorder point that prevents stock-outs and reviewing both as the account's work changes. Planned well, the shelf always holds the right size without tying up stock.

Key takeaways

  • XENOBONE is supplied in 5 cc units in 0.7–1.5 mm, 2–3 mm and 4–5 mm particle sizes.
  • Plan each particle size separately, from the account's real case mix.
  • Reorder points prevent stock-outs; review them as case volumes change.
  • An opened sterile unit cannot return to stock, so match the shelf to typical cases.

This article gives distributors and clinic managers a practical method for planning XENOBONE orders. The same approach applies to the COLL-OS membrane formats often ordered with it.

Why plan by particle size?

The three particle sizes are separate stock items. A clinic that uses mostly the 0.7–1.5 mm size gains nothing from a shelf full of 4–5 mm units. Treating XENOBONE as a single item and ordering evenly across sizes leads to some sizes running out while others sit unused.

Planning each size separately takes a little more effort at the start and saves waste and emergency orders later. It also gives the distributor a clearer picture of territory demand by size.

How do you estimate use?

Start with the cases. For each account, ask or estimate:

  • How many grafting cases it does in a typical month.
  • Which particle size it uses for each type of case.
  • How many 5 cc units a typical case uses.

Multiply cases by units per case for each particle size, and you have an estimated monthly use. The surgeon decides how much graft each case needs, so ask rather than assume; volumes vary widely between a single socket and a larger augmentation.

How should the reorder point be set?

A reorder point is the stock level at which a new order is placed. Set it so that stock does not run out while the new order is on its way. A simple formula is:

ElementMeaning
Use during delivery timeUnits used between ordering and delivery
Safety marginExtra units for busier periods or delays
Reorder pointThe sum of the two

For a clinic supplied by a local distributor with quick delivery, the reorder point may be low. For a distributor ordering from the manufacturer, it reflects the longer replenishment cycle and the combined demand of all accounts.

How much safety stock is sensible?

Safety stock protects against busy weeks and delays. Too little, and a clinic runs out on a surgery day. Too much, and stock ages on the shelf.

A practical rule is to hold enough safety stock to cover the largest case the account is likely to do at short notice, plus a small margin. For a surgical department doing larger defects, that may mean several units of the preferred size. For a general practice doing occasional sockets, one or two may be enough.

How do you avoid waste?

An opened sterile unit cannot go back on the shelf. Waste happens when a unit is opened and not used, or when stock passes its use-by date. To reduce both:

  • Plan the particle size before the appointment and open only what is needed.
  • Rotate stock so the earliest use-by date is used first.
  • Avoid overstocking slow-moving sizes.
  • Review use-by dates at each stock check.

Distributors can help by checking clinic shelves during visits and flagging units approaching their use-by date. A short note in the visit report keeps the clinic and the distributor aligned.

How should the plan be reviewed?

Review the plan regularly, for example every quarter. Compare actual reorders with the estimate for each particle size. If a size runs out often, raise its reorder point. If a size ages on the shelf, lower its stock or stop holding it at that account.

Changes in the account's work also trigger a review: a new surgeon joining, a new procedure being offered or a change in referral patterns. Ask about planned changes on each visit, so the plan moves before the shelf runs short rather than after. Our article on scalable supply chain solutions covers planning across a whole territory.

How should COLL-OS be planned alongside?

Where an account uses COLL-OS with XENOBONE, plan the membrane formats with the same method. COLL-OS comes in 1.25 × 2.5 cm, 1.5 × 2 cm, 2 × 3 cm and 2.5 × 2.5 cm. Track which membrane format is used with which particle size, and make sure the matching pair is in stock. Running out of the membrane while the graft is on the shelf, or the reverse, is a common frustration that planning avoids.

What records support good planning?

Good planning depends on records:

  • Distributor dispatch records by account, product, particle size and lot.
  • Clinic implant logs showing what was used and when.
  • Notes of opened but unused units.

Under the EU Medical Device Regulation, distributors keep supply records for traceability anyway. Using the same records for planning adds value at no extra cost. Our article on MDR compliance for distributors explains the record-keeping duties.

Talk to a DESU product specialist

For XENOBONE particle size codes, pack information or order planning support, write to sales@desu.tr, use the contact page, or request a quote.

Frequently asked questions

Is XENOBONE available in volumes other than 5 cc?

XENOBONE is supplied in 5 cc units. For larger volume options in a collagen and β-TCP graft, DESU offers DEBONE in 5, 10, 20 and 30 cc.

How often should a clinic count its XENOBONE stock?

Many clinics check stock weekly or before each surgical day. The aim is to reorder before reaching the reorder point.

What should happen to units near their use-by date?

Use them first if possible. If they are unlikely to be used in time, discuss options with the distributor rather than letting them expire on the shelf.

Should a distributor hold safety stock for every account?

Distributors usually hold safety stock centrally, based on combined demand, rather than a separate reserve for each account. Clinics then keep their own small safety margin on site.

Related standards

  • ISO 13485: Medical devices — Quality management systems
  • Regulation (EU) 2017/745 on medical devices (MDR)