XENOBONE Particle Sizes: Matching Graft to Defect
How the three XENOBONE particle sizes relate to different bone defects, how surgeons think about particle size and how distributors stock each of them.
XENOBONE is offered in three particle sizes, 0.7–1.5 mm, 2–3 mm and 4–5 mm, so that surgeons can choose a graft suited to different bone defects. Particle size influences how the graft fills and packs into a space. Smaller particles may be chosen for small or narrow defects and larger ones for bigger spaces, but the choice is the surgeon's, made for each case following the instructions for use.
Key takeaways
- XENOBONE comes in three particle sizes: 0.7–1.5 mm, 2–3 mm and 4–5 mm, each in 5 cc units.
- Particle size affects how a graft fills and packs into a defect.
- Surgeons choose particle size by defect size, shape and their own approach.
- Distributors stock by particle size from each account's actual reorders.
This article explains what particle size means for a particulate bone graft and how distributors can plan XENOBONE stock around it. For the membrane often used with it, see COLL-OS.
What does particle size mean for a bone graft?
A particulate graft is made up of many small pieces. Their size affects several things:
- How closely the particles pack together in the defect.
- The spaces left between particles.
- How easily the graft adapts to the shape of the defect.
- How the graft is handled and delivered to the site.
There is no single correct particle size. Different defects and different surgical approaches call for different choices, which is why XENOBONE is offered in three.
How do the three XENOBONE sizes compare?
| Particle size | General description | Typical consideration |
|---|---|---|
| 0.7–1.5 mm | Fine | Small or narrow defects; close adaptation |
| 2–3 mm | Medium | General-purpose; moderate defects |
| 4–5 mm | Coarse | Larger spaces |
All three share the same composition: Type I bovine collagen with β-TCP, osteoconductive and bioresorbable. Each is supplied in 5 cc units. The "typical consideration" column reflects general practice in particulate grafting, not an indication; the instructions for use set out how the product is used.
How do surgeons choose particle size?
Surgeons consider the size and shape of the defect, how many walls of bone surround it, the access to the site and their own training and experience. Some surgeons use one particle size for most cases; others switch depending on the defect. A few combine sizes.
A distributor does not need to know the reasoning in detail. It is enough to know that preferences are real and often firm, and to stock accordingly. When a surgeon changes preference, the reorders show it, so keep an eye on them after any change.
What questions should a rep ask?
To understand an account's needs, ask:
- Which particle size do you use most?
- Does your choice change with the type of defect?
- How much graft does a typical case use?
- How many grafting cases do you do in a typical week or month?
The answers give the opening order and the reorder point for each particle size. They also tell the rep which accounts may need more than one size.
How should stock be planned by particle size?
Plan each particle size separately. A common mistake is to treat XENOBONE as one product and order an even split. Real demand is rarely even.
A practical approach:
- Start each account with the particle sizes it says it uses.
- Record reorders by particle size for each account.
- After a few months, compare the territory's total demand by size with the stock you hold.
- Adjust the next order to match.
Practices focused on single sites often reorder the finer and medium sizes more. Surgical departments doing larger defects may use more of the coarse size. Our article on scalable supply chain solutions covers reorder planning in more detail.
How does particle size relate to membrane size?
Where a membrane covers the graft, the two choices are often linked. A small defect filled with fine particles may be covered with one of the smaller COLL-OS formats, 1.25 × 2.5 cm or 1.5 × 2 cm. A larger defect with coarser particles may be covered with one of the larger formats, 2 × 3 cm or 2.5 × 2.5 cm.
These are tendencies, not rules. The surgeon chooses both. For stocking, though, tracking which particle sizes and membrane formats each account orders together helps keep matching products on the shelf.
How should particle sizes be stored and picked?
Three particle sizes of the same product in similar packaging are easy to confuse. In the warehouse:
- Store each particle size in its own clearly labelled location.
- Pick by product code and particle size, not by appearance.
- Check the particle size on the label at dispatch.
- Record the lot and particle size for every delivery.
At the clinic, the same care applies. The nurse checks the particle size on the pack against the plan before opening it. Writing the planned particle size on the appointment plan, next to the membrane size if one is used, makes the check quick and removes guesswork during the procedure.
What should a rep avoid saying?
Avoid telling surgeons which particle size to use for a case. Avoid claiming that one size gives better results. Describe the options, explain that they suit different defects and let the surgeon choose. Our article on the science of xenografts gives background on bovine-derived grafts that reps can use in these conversations.
Talk to a DESU product specialist
For XENOBONE particle size codes, COLL-OS formats or stock planning support, write to sales@desu.tr, use the contact page, or request a quote.
Frequently asked questions
Are all XENOBONE particle sizes the same material?
Yes. All three are Type I bovine collagen with β-TCP, osteoconductive and bioresorbable. Only the particle size differs.
Can a surgeon mix XENOBONE particle sizes?
Some surgeons combine sizes. How the graft is used is the surgeon's decision, following the instructions for use.
Which XENOBONE size should a new account start with?
The size the surgeon says they use most. If they are unsure, the medium 2–3 mm size is a common starting point for discussion, but the surgeon decides.
How does a distributor know when to add a particle size for an account?
When the account asks for it, or when its cases change, for example a new surgeon or new procedures. Watch reorders and ask on visits whether the current sizes still cover the work.
Related standards
- ISO 13485: Medical devices — Quality management systems
- ISO 10993 series: Biological evaluation of medical devices