What Is in a Ventriculoperitoneal Shunt Kit? A Component Checklist

A component-by-component checklist of a DESU VP shunt kit: valve, catheters, stylet, connector, the optional extras and how the kit is supplied.
Key Takeaways
- Every DESU VP shunt kit has five core parts: valve, 23 cm ventricular catheter, 120 cm peritoneal catheter, stylet and right-angled connector.
- The valve is what differs between Defit, Decurve and Depus kits; the catheter dimensions are the same.
- An antisiphon device is optional on all three families, and Depus kits can also take a reservoir.
- Shunt systems are supplied sterile by ethylene oxide, for single use, in standard or antibiotic-impregnated configurations.
A DESU ventriculoperitoneal shunt kit contains five core components: a valve (Defit, Decurve or Depus), a 23 cm ventricular catheter with 1.3 mm inner and 2.5 mm outer diameter, a 120 cm peritoneal catheter with 1.1 mm inner and 2.5 mm outer diameter, a stylet and a right-angled connector. An antisiphon device can be added, and Depus kits can also include a reservoir.
This checklist is for theatre nurses preparing a case, stores teams receiving stock and buyers building a formulary for shunt systems.
What are the core components of a VP shunt kit?
| Component | Specification in DESU VP kits | Role in the shunt |
|---|---|---|
| Valve | Defit, Decurve or Depus; size and pressure as ordered | Regulates the flow of CSF from the ventricles |
| Ventricular catheter | Silicone, 23 cm; 1.3 mm inner, 2.5 mm outer diameter | Carries CSF from the ventricle to the valve |
| Peritoneal catheter | Silicone, 120 cm; 1.1 mm inner, 2.5 mm outer diameter | Carries CSF from the valve to the peritoneal cavity |
| Stylet | Supplied with the kit | Supports the ventricular catheter during passage |
| Right-angled connector | Supplied with the kit | Guides the catheter at an angle and organises the connection to the valve |
The catheter dimensions are identical across the Defit, Decurve and Depus kits. What changes from one family to the next is the valve, so the valve is where most ordering questions arise.
Which valve is in the kit?
Check the valve family, size and pressure on the label against the surgeon’s request before the kit is opened.
- Defit: flat-bottom silicone valve with no metal parts, in Ultra Small (35 mm overall length), Small (40 mm) and Regular (45 mm), each with low, medium or high fixed pressure.
- Decurve: round burr-hole silicone valve with a reservoir and no metal parts, in a paediatric size (23 mm nominal diameter) and an adult size (28 mm), each with low, medium or high fixed pressure.
- Depus: polysulfone valve with a ruby ball and titanium spring mechanism, in low, medium and high fixed pressures, plus adjustable valves in paediatric and adult sizes.
Adjustable Depus valves are read and set with the Depus Adjustment Kit, which has a locator, a compass and a magnet. It is a separate accessory, supplied non-sterile in a reusable case, in 3 Pressure and 5 Pressure versions. It is not part of the sterile shunt kit, so the hospital needs one on hand wherever adjustable valves are implanted or followed up. For a broader look at valve choice, see how teams evaluate a hydrocephalus shunt valve.
What should you check on the two catheters?
Both catheters are silicone and radiopaque, with tantalum length marks so their position can be followed on imaging.
- Ventricular catheter: 23 cm long, 1.3 mm inner and 2.5 mm outer diameter, tantalum marks at every centimetre from 5 to 15 cm, and 24 drainage holes in four rows of six in the proximal section.
- Peritoneal catheter: 120 cm long, 1.1 mm inner and 2.5 mm outer diameter, tantalum marks at every centimetre from 5 to 20 cm, and drainage holes along four rows at the proximal end.
- Colour: standard catheters are white; antibiotic-impregnated catheters are orange. The colour is a quick visual check that the configuration matches the order.
What do the stylet and right-angled connector do?
The stylet is a thin, stiff guide placed inside the ventricular catheter. It gives the soft silicone enough support to be passed along its planned path, and it is removed once the catheter is in place. Technique and the moment of removal follow the surgeon’s practice and the instructions for use.
The right-angled connector is DESU’s L-type catheter connector. It guides the ventricular or peritoneal catheter at an appropriate angle without kinking or clogging, and it organises the connection between the ventricular catheter and the valve. For more on this component, see the key advantages of L-type catheter connectors.
Which optional components can be added?
- Antisiphon device: optional on Defit, Decurve and Depus VP kits. It is designed to close immediately against the siphon effect that can occur when the peritoneal catheter moves from horizontal to vertical. Kits that include it have a reference code ending in “-ASD”.
- Reservoir (Depus): an antisiphon device and a reservoir can both be added to Depus kits according to clinical need. The Decurve valve already has a reservoir in its body.
Options change the kit code and the line item, so they should be agreed with the surgeon before the order is placed rather than at the time of the case.
How are antibiotic-impregnated kits configured?
In DESU antibiotic-impregnated components, the antibiotic is impregnated into the material and released in a controlled manner over 28 days. The configurations differ by family:
- Defit: impregnation of the valve body only, semi-antibiotic kits (standard valve with antibiotic-impregnated catheters) or full-antibiotic kits (impregnated valve body and impregnated catheters).
- Decurve: standard, semi-antibiotic-impregnated and full-antibiotic-impregnated systems.
- Depus: standard VP kits, or configurations with antibiotic-impregnated ventricular and peritoneal catheters; adjustable Depus kits can also have an impregnated valve body.
How is the kit supplied?
DESU shunt systems are supplied for single use and sterilised by ethylene oxide. They are CE marked and manufactured under ISO 13485 in DESU’s own cleanrooms in Ankara, Türkiye. Single use means the kit is opened for one patient and not reprocessed; anything left over is handled according to the hospital’s procedures and the instructions for use.
A receiving and pre-case checklist
- Family and valve: Defit, Decurve or Depus, with the size ordered.
- Pressure: low, medium or high, or the adjustable version.
- Suffix: “-ASD” present only if an antisiphon device was ordered.
- Antibiotic configuration: standard (white catheters) or impregnated (orange), and for Defit and Decurve, semi or full.
- Packaging: sterile barrier intact and within the date on the label.
- Accessories: Depus Adjustment Kit available if an adjustable valve is planned.
- Catheters only: if the order was for catheters without a valve, the item is the separate ventriculoperitoneal catheter kit, which has the same two catheters, a stylet and a right-angled connector.
Talk to a DESU product specialist
If you are standardising shunt kits across theatres or want to check a configuration before ordering, DESU’s product specialists can walk through the options with you. Write to sales@desu.tr, use the contact page, or request a quote.
Frequently Asked Questions
Can a DESU valve be ordered without the catheters?
Yes. Defit, Decurve and Depus are offered as a valve or as a VP shunt kit. The kit adds the 23 cm ventricular catheter, the 120 cm peritoneal catheter, the stylet and the right-angled connector, so check which one the order line refers to.
Do Defit, Decurve and Depus kits use different catheters?
No. All three use the same catheter dimensions: a 23 cm ventricular catheter with 1.3 mm inner and 2.5 mm outer diameter, and a 120 cm peritoneal catheter with 1.1 mm inner and 2.5 mm outer diameter. The valve is the part that changes.
How can staff tell an antibiotic-impregnated kit at a glance?
By colour and by the label. Antibiotic-impregnated catheters are orange and standard catheters are white. The label and reference code confirm the exact configuration, including whether the valve body is impregnated.
Is the Depus Adjustment Kit sterile?
No. It is supplied non-sterile in a dedicated reusable case and is not part of the sterile shunt kit. It is used to locate an adjustable Depus valve, check its pressure and set it.
Sources
- ISO 7197: Neurosurgical implants — Sterile, single-use hydrocephalus shunts and components
- ISO 11135: Sterilization of health-care products — Ethylene oxide
- ISO 13485: Medical devices — Quality management systems
Talk to a specialist about this topic
Reach our team directly for product selection, technical specifications, sample requests or distributor enquiries.
Related articles
- NeurosurgeryAntisiphon Device in Shunt Kits: How It Counters the Siphon Effect
- NeurosurgeryFlat-Bottom vs Burr-Hole Shunt Valves: Defit and Decurve Compared
- News from DESUHydrocephalus Shunt Valve Solutions: Why Teams Evaluate DESU
- NeurosurgeryFixed-Pressure vs Adjustable Shunt Valves: How the Choice Is Made
Comments
No comments yet. Be the first to write one.